How the ThermStar System works

The ThermStar System™ converts energy from commercial or industrial exhaust through a Lepido® heat recovery unit. A heat transfer fluid carries that energy through a closed liquid-loop to one or more HeatCore Hx™ delivery units. The recovered heat can then serve an approved air, water, boiler, or process load without mixing the particle-laden exhaust with the receiving medium.

The system, end to end, and where each part is covered in full

CAPTURE

Source side performance

ThermStar heat recovery begins with patented Particle Repellent Geometry.

The open, staggered tubular arrangement supports contaminant pass-through and stable airflow where conventional fins or plates may foul.

Particle-laden exhaust enters

Lint, grease, dust or moisture, at process temperature, straight off the existing hood or stack. No pre-filtration stage is introduced ahead of the unit.

Air leaves without its heat, and with its particles

What arrives in the airstream carries on out of it. The operating objective is sustained useful recovery with a practical maintenance burden, within the approved application range.

Lepido exhaust heat exchanger

Operating objective

Sustained useful recovery

Airflow

Stable pressure drop over time

Boundary

Within the approved application range

TRANSFER

Closed loop heat recovery and flexible energy delivery

A closed loop heat recovery system can connect a source to a useful demand located elsewhere in the facility. This separation supports flexible routing and helps protect the receiving process from direct contact with the exhaust stream. A glycol loop heat recovery configuration may be selected where environmental and operating conditions make that fluid appropriate.

The ThermStar System, exhaust to loadParticle-laden process exhaust enters a Lepido heat recovery unit. A closed liquid-loop carries the recovered energy to a HeatCore Hx delivery unit serving process or makeup air, process water or boiler feedwater. The two fluids never mix. ThermStar Power Intelligence reads both units.PARTICLE-LADEN SIDECLOSED LIQUID-LOOP — CLEAN SIDEPower IntelligenceProcessoven · washer · fryergrease · lint · sootLepido®HEAT RECOVERY UNIT · PRG®finless · staggered tube01heat transfer fluid, warmedHeatCore Hx™DELIVERY UNITone — or several03Process / makeup airProcess waterBoiler feedwater…and four morereturned to the heat recovery unit, cooledTHE TWO FLUIDS NEVER MIX
MONITORING

Controls and measured operation

ThermStar™ Power Intelligence manages operating logic, sensors, alarms, data and the performance calculation. What it reads is what gets reported.

Source air, in and out

The temperature either side of the heat recovery unit. The difference between the two is the energy taken out of the airstream, which is the number everything else is built on.

Loop supply and return

What the closed liquid-loop is actually carrying, against what the design case said it would. A drift between them is the first sign of anything wrong.

ThermStar System with Lepido source unit and fluid loop

Fluid flow and run time

Circulation against the design case, and the hours in which the source and the demand actually coincide, the overlap, not the runtime of either on its own.

Calculated thermal energy

Recovered energy under the approved method, with status and alarms beside it. This is the figure an incentive process asks to see.

ENGINEERED FOR YOUR FACILITY

Configuration and deployment

Every ThermStar System™ is engineered to match the facility’s exhaust conditions, thermal energy requirements, operating schedules, and existing infrastructure—maximizing energy recovery and seamless integration with existing operations.

Integrated Technology. Collaborative Deployment.

ThermStar™ provides the heat recovery and delivery equipment, controls, monitoring technology, and technical expertise to support successful system integration.

We collaborate with engineering firms, contractors, and project stakeholders throughout system design, integration planning, installation, commissioning, and performance verification.

This flexible approach brings together specialized technology, engineering expertise, and qualified installation professionals to deliver a fully integrated thermal energy recovery solution tailored to each facility.

Lepido installed on foundry exhaust
NEXT STEP

Evaluate your facility

The platform can serve a single exhaust source or form part of a broader energy program across multiple locations. Request an Assessment to identify the best available heat source, a productive use for the recovered energy, and the data required to evaluate the opportunity.

Heat recovery installation on a quick service restaurant roof
COMMON QUESTIONS

What to know before you start

Can the ThermStar System be installed in an existing facility

Yes. Retrofitting existing facilities is a core application of ThermStar System™. Its flexible, modular design allows recovered thermal energy to be delivered to existing process heating, makeup air, or water heating systems. Each installation is engineered around the facility’s equipment, operating requirements, and available space, with a focus on minimizing disruption to ongoing operations while maximizing energy savings.

A configuration may consider one or more receiving loads when their temperatures, capacities, schedules, locations, and control needs align with the available source. ThermStar evaluates the combined operating case before recommending an arrangement.

ThermStar System™ performance is measured using temperature, airflow, fluid flow, and operating data to calculate recovered thermal energy and associated energy savings. ThermStar™ Power Intelligence continuously monitors system performance, tracks energy recovery, and provides historical reporting to validate savings over time. Each system is engineered to match available exhaust energy with the facility’s process and preheating requirements, maximizing useful energy recovery and reducing fuel consumption.

Most applications are applicable. It depends upon exhaust composition, concentration, temperature, humidity, pressure constraints, cleaning practices, materials, safety requirements, and facility standards must be reviewed. ThermStar, in conjunction with key stakeholders, reviews heat recovery potential and applicability as part of the due diligence process.

No. The ThermStar System™ uses a closed-loop heat transfer design that keeps the exhaust stream completely separate from the air, water, or process fluids being heated. Thermal energy recovered by the Lepido® unit is transferred through a sealed fluid loop to the HeatCore Hx™ delivery unit. Only heat is transferred—not exhaust air, particulates, or contaminants—ensuring clean energy delivery without cross-contamination.