How the ThermStar System works
The ThermStar System™ converts energy from commercial or industrial exhaust through a Lepido® heat recovery unit. A heat transfer fluid carries that energy through a closed liquid-loop to one or more HeatCore Hx™ delivery units. The recovered heat can then serve an approved air, water, boiler, or process load without mixing the particle-laden exhaust with the receiving medium.
The system, end to end, and where each part is covered in full
Recovers energy out of particle-laden exhaust at the stack, without a filtration stage ahead of it.
Heat transfer fluid carries the energy to where the demand is. The two fluids never mix.
Hands the energy to an approved air, water, boiler or process load. Seven delivery targets.
Logic, sensors, alarms, and the calculated energy recovered.
Source side performance
ThermStar heat recovery begins with patented Particle Repellent Geometry.
The open, staggered tubular arrangement supports contaminant pass-through and stable airflow where conventional fins or plates may foul.
Particle-laden exhaust enters
Lint, grease, dust or moisture, at process temperature, straight off the existing hood or stack. No pre-filtration stage is introduced ahead of the unit.
Air leaves without its heat, and with its particles
What arrives in the airstream carries on out of it. The operating objective is sustained useful recovery with a practical maintenance burden, within the approved application range.
Operating objective
Sustained useful recovery
Airflow
Stable pressure drop over time
Boundary
Within the approved application range
Closed loop heat recovery and flexible energy delivery
A closed loop heat recovery system can connect a source to a useful demand located elsewhere in the facility. This separation supports flexible routing and helps protect the receiving process from direct contact with the exhaust stream. A glycol loop heat recovery configuration may be selected where environmental and operating conditions make that fluid appropriate.
Controls and measured operation
ThermStar™ Power Intelligence manages operating logic, sensors, alarms, data and the performance calculation. What it reads is what gets reported.
Source air, in and out
The temperature either side of the heat recovery unit. The difference between the two is the energy taken out of the airstream, which is the number everything else is built on.
Loop supply and return
What the closed liquid-loop is actually carrying, against what the design case said it would. A drift between them is the first sign of anything wrong.
Fluid flow and run time
Circulation against the design case, and the hours in which the source and the demand actually coincide, the overlap, not the runtime of either on its own.
Calculated thermal energy
Recovered energy under the approved method, with status and alarms beside it. This is the figure an incentive process asks to see.
Configuration and deployment
Every ThermStar System™ is engineered to match the facility’s exhaust conditions, thermal energy requirements, operating schedules, and existing infrastructure—maximizing energy recovery and seamless integration with existing operations.
Integrated Technology. Collaborative Deployment.
ThermStar™ provides the heat recovery and delivery equipment, controls, monitoring technology, and technical expertise to support successful system integration.
We collaborate with engineering firms, contractors, and project stakeholders throughout system design, integration planning, installation, commissioning, and performance verification.
This flexible approach brings together specialized technology, engineering expertise, and qualified installation professionals to deliver a fully integrated thermal energy recovery solution tailored to each facility.
Evaluate your facility
The platform can serve a single exhaust source or form part of a broader energy program across multiple locations. Request an Assessment to identify the best available heat source, a productive use for the recovered energy, and the data required to evaluate the opportunity.
Can the ThermStar System be installed in an existing facility
Yes. Retrofitting existing facilities is a core application of ThermStar System™. Its flexible, modular design allows recovered thermal energy to be delivered to existing process heating, makeup air, or water heating systems. Each installation is engineered around the facility’s equipment, operating requirements, and available space, with a focus on minimizing disruption to ongoing operations while maximizing energy savings.
Can the ThermStar System deliver energy to more than one load
A configuration may consider one or more receiving loads when their temperatures, capacities, schedules, locations, and control needs align with the available source. ThermStar evaluates the combined operating case before recommending an arrangement.
How is ThermStar System™ performance measured and verified?
ThermStar System™ performance is measured using temperature, airflow, fluid flow, and operating data to calculate recovered thermal energy and associated energy savings. ThermStar™ Power Intelligence continuously monitors system performance, tracks energy recovery, and provides historical reporting to validate savings over time. Each system is engineered to match available exhaust energy with the facility’s process and preheating requirements, maximizing useful energy recovery and reducing fuel consumption.
Is the ThermStar System suitable for every exhaust application
Most applications are applicable. It depends upon exhaust composition, concentration, temperature, humidity, pressure constraints, cleaning practices, materials, safety requirements, and facility standards must be reviewed. ThermStar, in conjunction with key stakeholders, reviews heat recovery potential and applicability as part of the due diligence process.
Can exhaust contaminants enter the air or fluid being heated
No. The ThermStar System™ uses a closed-loop heat transfer design that keeps the exhaust stream completely separate from the air, water, or process fluids being heated. Thermal energy recovered by the Lepido® unit is transferred through a sealed fluid loop to the HeatCore Hx™ delivery unit. Only heat is transferred—not exhaust air, particulates, or contaminants—ensuring clean energy delivery without cross-contamination.